repair clinic encourages you to perform
this procedure safely in this video we will show one or more of these icons to alert you when to use caution as with any repair be sure you’ve unplugged
the appliance before beginning your first step is to remove the top
panel screws and set the panel aside next depress the tabs on the control
panel and pull it off disconnect the wire harness removed the screws to release the
circuit board bracket remove the control bracket screws and pull the bracket off now removed the screws located at the
base of the dryer pull the lower panel out and then down
to detach reach into the lower cabinet to
disconnect the door switch and moisture sensor wire harnesses remove the screws at the bottom and at the top of the front panel remove the mounting screws located inside
the door and pull the panel off removed the lower bulkhead mounting
screws and loosen the upper screws removed the mounting screws from the
blower housing lift the bulkhead off the upper mounting
screws and set it aside if still intact remove the old dryer
belt by depressing the pulley to release the tension and threading the belt
from the pulley and motor shaft install the new dryer belt by placing it
rib side down along the outside of the drum and looping it around the tension pulley
and motor shaft in a zig zag formation rotate the drum to help aligned the belt now reinstall the bulkhead by aligning
it on the upper screws tighten the screws replaced the lower screws as well as the ones for the blower
housing reattach the front panel by lining it up
on the cabinet then secure it with the upper and lower screws as well as the screws inside the door reconnect the door switch and moisture
sensor wire harnesses slide the lower panel up into position and secure with the screws reinstall the control panel bracket reattach the circuit board bracket reconnect the control panels wire
harness and snap the panel back into place replaced the top panel secure with the screws and plug the appliance back in to make sure it’s functioning properly